SWITCH BOARD MANUFACTURE CATALOGUE
Please see the link below
CABLE TRAY PERFORATED TYPE
Cable tray are perforated, used to pull and spread electric cables in buildings.
Description: Box shape with or without cover
Materials: Galvanized steel, hot dipped, aluminum or powder coated
Specifications: In bar form, there are many different lengths required: 2m, 2.5m, 3m ... with a thickness of 1.2mm to 3.2mm.
CABLE TRAY TYPE
Cable tray are not perforated, used to pull and spread electric cables in buildings.
Description: Box shape with or without cover
Materials: Galvanized steel, hot dipped, aluminum or powder coated
Specifications: In bar form, there are many different lengths required: 2m, 2.5m, 3m ... with a thickness of 1.2mm to 3.2mm.
Truong Nam Hai Co.ltd, APFC panel design, manufacture, supply for project
Power quality is critical to efficient operation of equipment. One contributing element to power quality is power factor at Loads
Auto Power Factor Correction (APFC) aims to improve power factor and hence power quality, utilising capacitors to offset usually inductive loads, for motors. PFC systems increase the efficiency of power supply, delivering immediate cost savings on electricity and stabilization of power supply
The main distribution box for the branches. Usually installed behind LV-SB cabinets and in front of DB cabinets.
Main Low Voltage Switchboards of Truong Nam Hai Co., Ltd are the modular designed which can be tailor-made to meet the client’s exact specification. It can be a Line straight, L shape or the U shape to fit in your limit space switch room.
Assembled from standard parts, this versatile system can be modified during production or even on-site to keep up with any last-minute design changes and inspection before active operation at site.
The systems design with the modular system also allows us to join two or more frame sections together enabling a larger cubicle for housing bulky protection devices.
In-house testing to ensure our reliable & quality products.
General characteristics
Standard: IEC 61439-1 & 61439-2
Type Tested Assemblies: Yes, with 4000A.
Rated Insulation Voltage: 690VAC.
Rated Operational Voltage: 400VAC.
Rated Impulse Withstand Voltage: 6kV.
Degree of Pollution: 3.
Frequency: 50Hz.
Main Busbars: up to 6300A.
Rated Peak Withstand Current: 143kA.
Rated Short-time Current: 65kA / 1s.
Degree of Protection: up to 54.
Segregation Form: up to 4b.
Material: Steel Sheet.
Metal Sheet Thickness: 2mm.
External Surface Protection: Powder Coated.
Painting Thickness: more than 50 micro mm.
Standard Color: RAL 7032, 9002.
Standard Dimension :
High standard : 2150 mm
Width: From 600 to 2000 mm
Depth: From 600 to 1600 mm
Cable tray, non-perforated cable tray. Used to pull the wires, cables in the works
Description: Two straight parallel rods, connected by a central support. Bonded by a weld or bolt
Material: Galvanized steel, or dipped aluminum or powder coated
Specification: Rods, available in different lengths as required: 2m, 2.5m, 3m.
The Motor Control Centers are versatile solutions for the needs of the industry even with high nominal currents.
The MCC – system is used in realization of various types of solutions for the supply and control of electrical motors. With a wide range of selection, form 2b up to 4b, the outgoing units can be removable or fixed. The system also includes instrumentation cabinets, integrated power factor compensation solutions.
Our products are always delivered ready-to-install and special attention has been paid to the productivity of installation.
General characteristics:
Standard: IEC 61439-1 & 61439-2, IEC 60947-3
Rated Insulation Voltage: 690VAC
Rated Operational Voltage: 400VAC
Rated Impulse Withstand Voltage: 6kV
Degree of Pollution: 3
Frequency: 50Hz
Main Busbars: up to 3200A
Rated Peak Withstand Current: 143kA
Rated Short-time Current: 65kA / 1s
Degree of Protection: up to 54
Segregation Form: up to 4b
Material: Steel Sheet
Metal Sheet Thickness: 2mm
External Surface Protection: Powder coated
Painting Thickness: more than 50 micro mm.
Standard Color: RAL 7032, 9002
Standard Dimension:
High standard : 2150 mm
Width: From 600 to 2000 mm
Depth: From 600 to 1600 mm